Difference between revisions of "PolyGlove: a body-based haptic interface"

From AIRWiki
Jump to: navigation, search
(Project short description)
m
 
(12 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{{Project
 +
|title=PolyGlove: a body-based haptic interface
 +
|image=DSCN0522.JPG
 +
|short_descr=PolyGlove is a new kind of haptic interfaces, that try to overcome the borders of the present datagloves exploiting the EAP technology.
 +
|coordinator=GiuseppinaGini
 +
|tutor=PaoloBelluco;
 +
|students=GabrieleValentini
 +
|resarea=Robotics
 +
|restopic=Bio Robotics
 +
|start=2009/04/03
 +
|end=2009/04/03
 +
|status=Closed
 +
|level=Ms
 +
|type=Thesis
 +
}}
 
== '''Part 1: project profile''' ==
 
== '''Part 1: project profile''' ==
  
Line 18: Line 33:
 
is applied into the haptic interfaces field.
 
is applied into the haptic interfaces field.
  
=== Dates ===
 
Start date: 2008/01/01
 
 
End date: 2010/12/31
 
 
=== Website(s) ===
 
  
  
 
=== People involved ===
 
=== People involved ===
''put here the links to the AIRWiki pages associated to all the people working on the project''
 
 
''[by the way, please note that one of such pages is automatically created for every AIRLab user (yes, for you too) and that you MUST have filled it in - complete with a photo - before entering the lab for the first time]''
 
  
 
===== Project head(s) =====
 
===== Project head(s) =====
Line 43: Line 49:
 
Gabriele Valentini - [[User:GabrieleValentini]]
 
Gabriele Valentini - [[User:GabrieleValentini]]
  
 +
== '''Part 2: project description''' ==
  
== '''Part 2: project description''' ==
+
=== Introduction ===
 +
This thesis project can be collocated into the robotics field, that science that
 +
proposes itself to integrate, in intelligent manner, perception and action.
 +
Into this field, the specific subarea of research is the haptic interfaces area,
 +
where are studied solutions to address the need of interacting with remote
 +
and virtual words, and in special way the project belongs to the body-
 +
based haptic interfaces. Thats devices that use the user's body as the force
 +
reaction base and have the inherent characteristics of being mobile, and
 +
therefore overcame the location dependency limitation.
 +
The purpose of this thesis is design and build a dataglove able to overcame
 +
the borders of the actual haptic interfaces. These borders are linked to the
 +
technologies used for develop the interfaces, that make difficult the integra-
 +
tion of force and tactile feedbacks into the same device. The main goal of
 +
the project is realize a device complete of force and tactile feedbacks, that
 +
at the same time guarantees wearability, comfort and movement freedom.
 +
The keyword of the solutions design is EAP, or better, the electroactive
 +
polymers technology. These new materials are plastics and gels thats show
 +
mechanical behaviors due to an electrical stimulation, and vice versa. They
 +
can be used as new kind of sensors and actuators, making possible overcame
 +
the limits of traditional technologies.
 +
==== Brief description of the work ====
 +
PolyGlove is the fruit of this research, a dataglove that base all his systems
 +
on the EAPs technology. The work did can be subdivided in several different
 +
1.3. Structure of the thesis 2
 +
phase.
 +
The first step was a global design of the whole glove, or better, was find a
 +
realizable solution for all the systems needed without project it in the de-
 +
tails. For the position/motion feed is proposed the use of two polymers: a
 +
piezoelectric PVDF film, and a piezoresistive CE silicon. This polymers can
 +
works as sensors, producing an electrical field (PVDF) or presenting changes
 +
in resistence (CE). For the force feedback, is proposed a double solution of
 +
active and passive feedback. Pistons full of ERF polymers and linked to
 +
the hand's fingers, can be driven in voltage in order to change the viscosity
 +
of the
 +
uid and to favor or obstruct the movement passively. The active
 +
side of force feedback is constituted by artificial tendons made of elastomer
 +
polymers. Concluding, the tactile feedback use PVDF as actuators in order
 +
to produce vibrations on the hand's palm. Special ciliary fingertips based
 +
on IPMC can return a texture perception.
 +
In a second phase, the design and develop process of the glove is started from
 +
the posistion/motion feed system. A first prototype is constituted by a glove
 +
equipped with four PVDF sensors, a control system able to sampling the
 +
sensors and to send the results to the remote side via wireless connection.
 +
This control system is made by different modules, in order to simplify the
 +
prototyping phase and to allow the reuse of the single modules. The brain
 +
of the system is a PIC18F2420 microcontroller equipped of an external 12
 +
bit ADC, the wireless communications are guarantee by an XBee module,
 +
a switching voltage regulator manage the batteries and a customized sensor
 +
board process the sensors signals.
 +
When the prototype was ready, a phase of test on the glove is started. This
 +
tests were subdivided into hardware settings test, and sensor's characteriza-
 +
tion tests. The hardware tests make possible to find the proper configuration
 +
of several parameters like frequency of sampling, filtering and so on. While
 +
the practical tests have given results about sensor's behavior, showing good
 +
skills and evidencing some weak points of the system.
 +
At the end of this work, the critical conclusions have been made showing the
 +
good characteristics of piezoelectric films as motion sensors, and evidencing
 +
the problems of the system. In order to complete the work, the basic guide-
 +
lines of the future works are presented. This guidelines explains how to fix
 +
the problems and show the way of future developing works.
 +
 
 +
=== Future works ===
  
 +
==== HW architecture ====
 +
The hardware developed during this work present advantages from one side
 +
and disadvantages from the other side. The mainly advantages are the mod-
 +
ularity and the fast prototyping due to the technologies chosen. For instance,
 +
the control board is so general purpose that can be used in the future tests
 +
of the others feedback without modify it. The same reasoning can be did
 +
for the source and communication boards.
 +
The main disadvantage is the size of the circuit. Only to test a part of
 +
the position/motion feed, it been covered all the arm by electrical circuits.
 +
Thinking to the future, when all the feedbacks will be ready, the need of
 +
space for the glove will be great. An other point that need to enhancements
 +
is the main architecture of the modules.
 +
In order to minimize the electrical circuits, different technologies must be
 +
considered. The Pin Through Hole (PTH) technology is very useful for a
 +
fast prototyping, but need to much space and limit the complexity of the
 +
boards. The solution is given by the Surface Mount Technology (SMT) that
 +
is a method to realize electronic circuits in witch the component are mounted
 +
directly onto the surface of the Printed Circuit Boards (PCBs). By the way,
 +
SMT give a lot of advantages like: reduce the space needed and the size of
 +
the components, the boards need to less energy for work, components can
 +
be placed on both sides of the boards, reduce the costs and so on.
 +
An example of the capacity of SMT is presented in the upper figure. The
 +
switching regulator and all his components can be "compressed", thanks to
 +
SMT, into a box smaller than a stamp. The gain in space is evident, this
 +
regulator is 7-8 times more small than our regulator.
 +
Thanks to this new feature, is possible to realize small independent modules
 +
for each feed/feedbacks. Every modules can be supplied by a microcontroller
 +
dedicated only to that purpose. Following this way, is possible to design the
 +
modules in a different manner. For instance, the position/motion feed don't
 +
need to a microcontroller so big like PIC18F2420, but it can be replaced by
 +
a smaller one.
 +
This choice reduce the computational load for every microcontroller exploit-
 +
ing the parallel calculate. On the head of the varied modules can be placed
 +
the Xbee. In fact, the Xbee is not only a wireless system, but it is supplied
 +
by several analog and digital lines. Designing a proper circuit, the Xbee can
 +
work like router for every modules, analyzing the packets and addressing
 +
their to the right modules.
 +
Concluding, the hardware need to some improvements. SMT technology
 +
simplify the electrical circuits, and make possible realize small modules for
 +
each feedbacks. Using the Xbee like router for the modules, the future hard-
 +
ware will be composed only by a module for position/motion feed, one for
 +
force feedback, one for tactile feedback, the SMT regulator and the Xbee.
 +
If the battery pack will be decentralized onto the high part of the arm, the
 +
whole structure can be placed in a small bracelet.
  
 +
==== SW Architecture ====
 +
At this point of the project, PolyGlove is not supplied by a proper software
 +
architecture, but it work only with simple MATLAB commands. MATLAB
 +
is surely the best choice for the prototyping phase of the project, but when
 +
the feedbacks will be ready, PolyGlove will need to something much articu-
 +
lated.
 +
The first need after have complete the feedbacks will be a solid commu-
 +
nication protocol. When the Xbee will work as router for the modules,
 +
the communication protocol will be fundamental for the whole device. The
 +
protocol must be light, with a mechanism of errors control and stable. Poly-
 +
Glove, when ultimate, will need and will produce a great amount of data,
 +
and this data will stream through the XBee.
 +
The second need of the glove will be a low level API for communicate with
 +
the device. Basing the architecture onto open source API like Chai3d, the
 +
future works of this side will be develop a low level architecture able to link
 +
the hardware with the hight level software, in order to provide an easy way
 +
to write demos for the glove.
  
[[Image:DSCN0522.JPG|thumb|right|300px|]]
+
==== Position/Motion feed====
 +
How viewed from the tests, the part of position/motion feed developed need
 +
to improve same points in order to solve problems. From the other side,
 +
there are a lot of new works to do for finish the developing process of the
 +
feed. In the next rows will be presented the guidelines for fix the problems
 +
coming from the tests and for finish the undeveloped points of the feed.
 +
===== Sensor's shape and size =====
 +
As viewed in section 6:2, Polyglove suffer
 +
of some problems due to the improper shape and size of the PVDFs, prob-
 +
lems such the reciprocal disturb of the sensors.
 +
The sensors used have a rectangular shape of about 2:5 per 1 cm, and these
 +
shape is the cause of the problems. Piezoelectric film is available in a va-
 +
riety of different film sizes and thicknesses. These can be fabricated into
 +
simple transducers, or for use as full size sheet for other application. This
 +
virgin sheets are available without electrodes attachments and wires. Start-
 +
ing from these sheets, instead from prefabricated sensors, make possible to
 +
realize customized sensor's shapes. If rightly positioned, the sensors can be
 +
drastically reduced in size.
 +
Reducing the sizes and customizing the shapes can solve the reciprocal dis-
 +
turb problem. By the way, this choice improve the glove performance, reduce
 +
the cost about sensors and make possible realize sensors for all the fingers.
  
Just to give you some ideas:
+
===== PVDF characterization =====
* state of the art;
+
Another point that need to be complete
* preliminary studies and sketches;
+
is the PVDFs characterization as sensors. The future works should be con-
* design notes and guidelines;
+
tinue the study on the PVDF skills and find a proper mathematical model
* link to project documents and files (you can upload them using the [[Special:Upload]] page);
+
for transform the voltage level into position/motion informations.
* description and results of experiments;
+
In order to complete the characterization, a secondary position system is
* photos and videos (they must have been uploaded with [[Special:Upload]] before you can insert them into this page);
+
needed. Several solutions are possible: mechanical structure with poten-
* link to source code of the software written for the project (you can upload it with [[Special:Upload]]);
+
tiometers, piezoresistive bend sensors, hall effect sensor and many others.
* advice about the configuration and the use of hardware and software;
+
Due to the only momently need of this system, the technology chosen is not
* useful internet links;
+
very important, but design a structure that will not in
* anything else that you think is useful to describe the project or could help people who will work on it in the future. Think about what ''you'' would have liked to find clearly explained when you started your work, instead of discovering it all by yourself the hard way. (By the way, if some of those missing information belong to other pages of this wiki, please update those pages: future users will be grateful.)
+
uence the PVDF
 +
behaviors is the real goal of this future work.
 +
When the supporting system will be ready, the process of characterization
 +
will continue and the next step will be find a mathematical model for the
 +
sensor. A way for do this is constituted by the neural networks. This math-
 +
ematical model can help the characterization process. By the way, with the
 +
supporting position system the developing process of the networks will be
 +
automatized in his major part.
 +
===== CE polymers =====
 +
Another future work is constituted by the piezoresis-
 +
tive CE. How just said in the previous chapters, this polymer make possible
 +
realize a variable resistive circuit on the upper side of the hand. The future
 +
works along this way will be realize a prototype for the glove and start a
 +
mathematical analysis of his work.
 +
The weakness of this polymer is the slowly change of resistence due to a
 +
movement. This skill make it perfect as statically position recognizer but
 +
make difficult use it during the dynamic phases. Now the situation is: from
 +
a side the fast and dynamic PVDF films and from the other the slow and
 +
static CE silicons. Integrating the data from PVDFs and CEs can make
 +
possible realize the final position/motion feed system.
 +
By the way, the data coming through the CEs can be used directly into
 +
the PVDF's neural network realizing a unique mathematical model, or can
 +
be created two different preprocessing models for the systems and a third
 +
mechanism that take and merge data for the final use.

Latest revision as of 12:28, 3 October 2011

PolyGlove: a body-based haptic interface
Image of the project PolyGlove: a body-based haptic interface
Short Description: PolyGlove is a new kind of haptic interfaces, that try to overcome the borders of the present datagloves exploiting the EAP technology.
Coordinator: GiuseppinaGini (gini@elet.polimi.it)
Tutor: PaoloBelluco (belluco@elet.polimi.it)
Collaborator:
Students: GabrieleValentini (gabriele.valentini@mail.polimi.it)
Research Area: Robotics
Research Topic: Bio Robotics
Start: 2009/04/03
End: 2009/04/03
Status: Closed
Level: Ms
Type: Thesis

Part 1: project profile

Project name

PolyGlove: a body-based haptic interface

Project short description

PolyGlove is a new kind of haptic interfaces, that try to overcome the borders of the present datagloves exploiting the EAP technology. This glove belongs to the body-based haptic interfaces, interfaces that use the user's body as force reaction base. EAPs, or better electroactive polymers, are materials that exhibit physical behaviors in response to an electrical stimulation, or vice versa, return an electrical signal in response to a physical stimulus. These materials can work as sensors and actuators, and thanks to their skills they can represent a solution at the previously mentioned limits. In this paper is presented the synthesis of a work where the EAP technology is applied into the haptic interfaces field.


People involved

Project head(s)

Prof.ssa Giuseppina Gini - User:GiuseppinaGini

Other Politecnico di Milano people

Ing. Paolo Belluco - User:PaoloBelluco

Students currently working on the project

Gabriele Valentini - User:GabrieleValentini

Part 2: project description

Introduction

This thesis project can be collocated into the robotics field, that science that proposes itself to integrate, in intelligent manner, perception and action. Into this field, the specific subarea of research is the haptic interfaces area, where are studied solutions to address the need of interacting with remote and virtual words, and in special way the project belongs to the body- based haptic interfaces. Thats devices that use the user's body as the force reaction base and have the inherent characteristics of being mobile, and therefore overcame the location dependency limitation. The purpose of this thesis is design and build a dataglove able to overcame the borders of the actual haptic interfaces. These borders are linked to the technologies used for develop the interfaces, that make difficult the integra- tion of force and tactile feedbacks into the same device. The main goal of the project is realize a device complete of force and tactile feedbacks, that at the same time guarantees wearability, comfort and movement freedom. The keyword of the solutions design is EAP, or better, the electroactive polymers technology. These new materials are plastics and gels thats show mechanical behaviors due to an electrical stimulation, and vice versa. They can be used as new kind of sensors and actuators, making possible overcame the limits of traditional technologies.

Brief description of the work

PolyGlove is the fruit of this research, a dataglove that base all his systems on the EAPs technology. The work did can be subdivided in several different 1.3. Structure of the thesis 2 phase. The first step was a global design of the whole glove, or better, was find a realizable solution for all the systems needed without project it in the de- tails. For the position/motion feed is proposed the use of two polymers: a piezoelectric PVDF film, and a piezoresistive CE silicon. This polymers can works as sensors, producing an electrical field (PVDF) or presenting changes in resistence (CE). For the force feedback, is proposed a double solution of active and passive feedback. Pistons full of ERF polymers and linked to the hand's fingers, can be driven in voltage in order to change the viscosity of the uid and to favor or obstruct the movement passively. The active side of force feedback is constituted by artificial tendons made of elastomer polymers. Concluding, the tactile feedback use PVDF as actuators in order to produce vibrations on the hand's palm. Special ciliary fingertips based on IPMC can return a texture perception. In a second phase, the design and develop process of the glove is started from the posistion/motion feed system. A first prototype is constituted by a glove equipped with four PVDF sensors, a control system able to sampling the sensors and to send the results to the remote side via wireless connection. This control system is made by different modules, in order to simplify the prototyping phase and to allow the reuse of the single modules. The brain of the system is a PIC18F2420 microcontroller equipped of an external 12 bit ADC, the wireless communications are guarantee by an XBee module, a switching voltage regulator manage the batteries and a customized sensor board process the sensors signals. When the prototype was ready, a phase of test on the glove is started. This tests were subdivided into hardware settings test, and sensor's characteriza- tion tests. The hardware tests make possible to find the proper configuration of several parameters like frequency of sampling, filtering and so on. While the practical tests have given results about sensor's behavior, showing good skills and evidencing some weak points of the system. At the end of this work, the critical conclusions have been made showing the good characteristics of piezoelectric films as motion sensors, and evidencing the problems of the system. In order to complete the work, the basic guide- lines of the future works are presented. This guidelines explains how to fix the problems and show the way of future developing works.

Future works

HW architecture

The hardware developed during this work present advantages from one side and disadvantages from the other side. The mainly advantages are the mod- ularity and the fast prototyping due to the technologies chosen. For instance, the control board is so general purpose that can be used in the future tests of the others feedback without modify it. The same reasoning can be did for the source and communication boards. The main disadvantage is the size of the circuit. Only to test a part of the position/motion feed, it been covered all the arm by electrical circuits. Thinking to the future, when all the feedbacks will be ready, the need of space for the glove will be great. An other point that need to enhancements is the main architecture of the modules. In order to minimize the electrical circuits, different technologies must be considered. The Pin Through Hole (PTH) technology is very useful for a fast prototyping, but need to much space and limit the complexity of the boards. The solution is given by the Surface Mount Technology (SMT) that is a method to realize electronic circuits in witch the component are mounted directly onto the surface of the Printed Circuit Boards (PCBs). By the way, SMT give a lot of advantages like: reduce the space needed and the size of the components, the boards need to less energy for work, components can be placed on both sides of the boards, reduce the costs and so on. An example of the capacity of SMT is presented in the upper figure. The switching regulator and all his components can be "compressed", thanks to SMT, into a box smaller than a stamp. The gain in space is evident, this regulator is 7-8 times more small than our regulator. Thanks to this new feature, is possible to realize small independent modules for each feed/feedbacks. Every modules can be supplied by a microcontroller dedicated only to that purpose. Following this way, is possible to design the modules in a different manner. For instance, the position/motion feed don't need to a microcontroller so big like PIC18F2420, but it can be replaced by a smaller one. This choice reduce the computational load for every microcontroller exploit- ing the parallel calculate. On the head of the varied modules can be placed the Xbee. In fact, the Xbee is not only a wireless system, but it is supplied by several analog and digital lines. Designing a proper circuit, the Xbee can work like router for every modules, analyzing the packets and addressing their to the right modules. Concluding, the hardware need to some improvements. SMT technology simplify the electrical circuits, and make possible realize small modules for each feedbacks. Using the Xbee like router for the modules, the future hard- ware will be composed only by a module for position/motion feed, one for force feedback, one for tactile feedback, the SMT regulator and the Xbee. If the battery pack will be decentralized onto the high part of the arm, the whole structure can be placed in a small bracelet.

SW Architecture

At this point of the project, PolyGlove is not supplied by a proper software architecture, but it work only with simple MATLAB commands. MATLAB is surely the best choice for the prototyping phase of the project, but when the feedbacks will be ready, PolyGlove will need to something much articu- lated. The first need after have complete the feedbacks will be a solid commu- nication protocol. When the Xbee will work as router for the modules, the communication protocol will be fundamental for the whole device. The protocol must be light, with a mechanism of errors control and stable. Poly- Glove, when ultimate, will need and will produce a great amount of data, and this data will stream through the XBee. The second need of the glove will be a low level API for communicate with the device. Basing the architecture onto open source API like Chai3d, the future works of this side will be develop a low level architecture able to link the hardware with the hight level software, in order to provide an easy way to write demos for the glove.

Position/Motion feed

How viewed from the tests, the part of position/motion feed developed need to improve same points in order to solve problems. From the other side, there are a lot of new works to do for finish the developing process of the feed. In the next rows will be presented the guidelines for fix the problems coming from the tests and for finish the undeveloped points of the feed.

Sensor's shape and size

As viewed in section 6:2, Polyglove suffer of some problems due to the improper shape and size of the PVDFs, prob- lems such the reciprocal disturb of the sensors. The sensors used have a rectangular shape of about 2:5 per 1 cm, and these shape is the cause of the problems. Piezoelectric film is available in a va- riety of different film sizes and thicknesses. These can be fabricated into simple transducers, or for use as full size sheet for other application. This virgin sheets are available without electrodes attachments and wires. Start- ing from these sheets, instead from prefabricated sensors, make possible to realize customized sensor's shapes. If rightly positioned, the sensors can be drastically reduced in size. Reducing the sizes and customizing the shapes can solve the reciprocal dis- turb problem. By the way, this choice improve the glove performance, reduce the cost about sensors and make possible realize sensors for all the fingers.

PVDF characterization
Another point that need to be complete

is the PVDFs characterization as sensors. The future works should be con- tinue the study on the PVDF skills and find a proper mathematical model for transform the voltage level into position/motion informations. In order to complete the characterization, a secondary position system is needed. Several solutions are possible: mechanical structure with poten- tiometers, piezoresistive bend sensors, hall effect sensor and many others. Due to the only momently need of this system, the technology chosen is not very important, but design a structure that will not in uence the PVDF behaviors is the real goal of this future work. When the supporting system will be ready, the process of characterization will continue and the next step will be find a mathematical model for the sensor. A way for do this is constituted by the neural networks. This math- ematical model can help the characterization process. By the way, with the supporting position system the developing process of the networks will be automatized in his major part.

CE polymers

Another future work is constituted by the piezoresis- tive CE. How just said in the previous chapters, this polymer make possible realize a variable resistive circuit on the upper side of the hand. The future works along this way will be realize a prototype for the glove and start a mathematical analysis of his work. The weakness of this polymer is the slowly change of resistence due to a movement. This skill make it perfect as statically position recognizer but make difficult use it during the dynamic phases. Now the situation is: from a side the fast and dynamic PVDF films and from the other the slow and static CE silicons. Integrating the data from PVDFs and CEs can make possible realize the final position/motion feed system. By the way, the data coming through the CEs can be used directly into the PVDF's neural network realizing a unique mathematical model, or can be created two different preprocessing models for the systems and a third mechanism that take and merge data for the final use.