Difference between revisions of "Predictive BCI Speller based on Motor Imagery"
(New page: == '''Part 1: Project profile''' == === Project name === BCI based on Motor Imagery === Project short description === This project is aimed is to control an external device through the...) |
|||
Line 42: | Line 42: | ||
== '''Part 2: Project description''' == | == '''Part 2: Project description''' == | ||
− | + | The goal of this project is to implement a BCI system supporting people with motor disabilities to communicate effectively. | |
+ | The main idea is to adopt the "virtual keyboard" paradigm in which a series of symbols are selected by means of a BCI interface. | ||
+ | |||
+ | This kind of communication can be included in the class of Alternative and Augmentative Communication (AAC) and the main issue with it is in the need of minimizing the number of selections required by the user while running the application. Indeed the selection process could be costly (both in terms of time and effort) for the target users of these kinds of systems. | ||
+ | |||
Revision as of 09:48, 18 October 2008
Part 1: Project profile
Project name
BCI based on Motor Imagery
Project short description
This project is aimed is to control an external device through the analysis of brain waves measured on the human scalp.
Dates
Start date: 01/05/2008
End date:
Website(s)
People involved
Project head(s)
- Matteo Matteucci (professor)
- Sbattella Licia (professor)
Other Politecnico di Milano people
- Rossella Blatt (phd student)
Students currently working on the project
- Tiziano D'Albis (master student)
Laboratory work and risk analysis
Laboratory work for this project will be mainly performed at AIRLab-IIT/Lambrate. The main activity consists in the acquisition of brain signals through an EEG amplifier for on-line or off-line processing. This is a potentially risky activity since there is an electrical instrumentation that is in direct contact with the human body. It is thus important to keep the system isolated from the power line. The EEG amplifier (as all biomedical instrumentations) is certified by the vendor to be isolated and the acquired data are transferred to the PC using an optic fiber connection . Anyhow for increased safety the PC and any other electronic device connected to the system must be disconnected from the power line. Standard safety measures described in Safety norms will be followed.
Part 2: Project description
The goal of this project is to implement a BCI system supporting people with motor disabilities to communicate effectively. The main idea is to adopt the "virtual keyboard" paradigm in which a series of symbols are selected by means of a BCI interface.
This kind of communication can be included in the class of Alternative and Augmentative Communication (AAC) and the main issue with it is in the need of minimizing the number of selections required by the user while running the application. Indeed the selection process could be costly (both in terms of time and effort) for the target users of these kinds of systems.
Part 3: References
- Control of two-dimensional movement signals by a noninvasive brain-computer interface in humans, Wolpaw J.R., McFarland J., PNAS, vol. 101, no. 51, december 2004, pages 17849-17854.
- Brain Computer interfaces for communication and control, Wolpaw J.R., Birbaumer N., McFarland D., Pfurtsheller G., Vaughan T., Clinical Neurophysiology 113, 2002, 767-791
- EEG based communication: prospects and problems, Vaughan T., Wolpaw J.R., Donchin E., IEEE transactions on rehabilitation engineering, vol. 4, no. 4, december 1996, pages 425-430.